天津农学院学报 ›› 2019, Vol. 26 ›› Issue (4): 95-99.doi: 10.19640/j.cnki.jtau.2019.04.019

• 研究与简报 • 上一篇    下一篇

二维相关谱技术在荧光谱重叠峰解析中的应用

张婧, 柳春雨, 连增艳, 杨延荣, 孙国红, 杨仁杰通信作者   

  1. 天津农学院 工程技术学院,天津 300384
  • 收稿日期:2019-06-12 发布日期:2020-01-19
  • 通讯作者: 杨仁杰(1978-),男,教授,博士,主要从事光谱检测技术与应用方面的研究。E-mail:rjyang1978@163.com。
  • 作者简介:张婧(1995-),女,硕士在读,主要从事光谱检测方面的研究。E-mail:15737313523@163.com。
  • 基金资助:
    国家自然科学基金面上项目(41771357, 21607114, 31201359); 天津市应用基础与前沿技术研究计划项目(18JCYBJC96400,14JCYBJC30400)

Implementation of fluorescence spectral overlap resolution using two-dimensional fluorescence correlation spectroscopy

ZHANG Jing, LIU Chun-yu, LIAN Zeng-yan, YANG Yan-rong, SUN Guo-hong, YANG Ren-jieCorresponding Author   

  1. College of Engineering and Technology, Tianjin Agricultural University, Tianjin 300384, China
  • Received:2019-06-12 Published:2020-01-19

摘要: 多环芳烃是重要的环境污染物,环境中的多环芳烃残留量低、种类繁多,常规荧光光谱法难以对复杂体系中的多环芳烃重叠荧光峰进行有效解析。采用二维荧光相关谱方法对苯并[a]芘、苯并[ghi]苝、苯并[k]荧蒽三种多环芳烃的混合溶液进行荧光峰解析。配置三种多环芳烃混合溶液,共30个样本,并采集其随浓度变化的一维动态荧光谱。在此基础上,以浓度为外扰,分别对动态荧光谱进行同步和异步二维相关谱计算。以一维荧光光谱图中未被覆盖的500 nm苯并[ghi]苝荧光峰为线索,根据同步谱中交叉峰的正负和异步谱中交叉峰的有无,推断出405、425、459和491 nm处的荧光峰来自于苯并[a]芘;471、480和500 nm处的荧光峰来自于苯并[ghi]苝;417、433和443 nm处的荧光峰来自于苯并[k]荧蒽。研究结果表明,二维荧光相关谱技术可以实现复杂体系中多种多环芳烃重叠荧光峰的有效解析,能够提供更多的光谱特征信息。

关键词: 二维荧光相关谱技术, 苯并[a]芘, 苯并[ghi]苝, 苯并[k]荧蒽, 重叠峰, 解析

Abstract: :Polycyclic aromatic hydrocarbons(PAHs), which have low residual amounts and various types, are important environmental pollutants. It is difficult to analyze the overlapping fluorescent peaks of PAHs in complex systems by conventional fluorescence spectroscopy. Two-dimensional(2D)fluorescence correlation spectroscopy was used to analyze the fluorescence peaks of a mixture of three PAHs, benzo[a]pyrene, benzo[ghi]pyrene and benzo[k]fluoranthene. A total of 30 mixed solution samples were prepared, and the one-dimensional(1D)fluorescence spectra were collected. On this basis, synchronous and asynchronous 2D correlation spectra were calculated for the 1D dynamic fluorescence spectra under the external disturbance of PAHs concentration. Based on the uncovered fluorescence peak of benzo[ghi]perylene at 500 nm in 1D fluorescence spectra, the sources of overlapping peaks were confirmed in mixed solutions in terms of the positive and negative cross peaks in synchronous spectra and the presence or absence of cross peaks in asynchronous spectra. The fluorescence peaks at 405, 425, 459 and 491 nm were assigned to benzo[a]pyrene; the fluorescent peaks at 471, 480 and 500 nm were assigned to benzo[ghi]perylene; the fluorescent peaks at 417, 433 and 443 nm were assigned to benzo[k]fluoranthene. The results showed that 2D fluorescence correlation spectroscopy can effectively resolve the overlapping fluorescent peaks of PAHs in complex systems and provide more spectral characteristics information.

Key words: two-dimensional fluorescence correlation spectroscopy, benzo[a]pyrene, benzo[ghi]perylene, benzo[k]fluorene, overlapping peak, resolution

中图分类号: